Timber frame wall - Insulation between studs & airtight seal at ceiling junction with Solitex Plus

Drawing C

Detailed View

Drawing C
Number Description
1 Concrete Block outer leaf
2 Ventilated Cavity
3 Solitex WA breather membrane
4 OSB Sheathing
5 Homatherm Holzflex 040 natural insulation
6 DB+ Variable vapour check
7 Rapid Cell Quick Tape
8 Plasterboard
9 First floor
10 Airtight seal using Solitex Plus breather membrane